CONTROL UNIT

Brand COBO Product Code 1007940

Code: 01171064.02

Doc. Code: 01171064_$2

€82.40
Tax excluded
(100.53 € Tasse incluse)

Quantity

  • SSL 100% secure website
  • Fast shipping with national and international couriers
Description WORKING
Switching the engine on, when pin T is at +12V, the output is activated (pin53S=+12V) and the
signal in frequency on pin31 is checked. If the frequency is higher than 150Hz, the output is
deactivated; otherwise it remains ON for max 25 sec. If input T switches to Open before 25-sec
time ends, the output is switched to Open too. Whatever the state of pin T is, it is not possible to
start the engine twice; once the output is deactivated, it cant switch to +12V.
Restart is possible only when the control unit starts being power supplied again (pin15).
POWER SUPPLY VOLTAGE V
12V
MAX LOAD
5 A
APPLICATIONS
[application-text]
Reference 1007940